1000kg Batch Freeze Dryer

1000kg Batch Freeze Dryer
1000kg Batch Freeze Dryer
Price And Quantity
  • 1
  • Set/Sets
    Product Description

    Our in-depth knowledge and industrial expertise has enabled us to emerge as a reputed manufacturer and supplier of 1000kg Batch Freeze Dryer. The vacuum system of this dryer has dual system; the pre-pumping unit and the maintenance unit, improve the stability and durability of the system. Our dexterous manpower uses quality grade materials to manufacture this dryer. This 1000kg Batch Freeze Dryer can be used in the drying of serum, plasma, vaccines, enzymes, hormones and so on.

    Features:

    • Longer service life
    • Robust construction
    • Maintenance free
    1000kg Batch Freeze Dryer

    Technical parameters of freeze dryer :

    Model

    EBT-1000

    Type

    Radiant type with individual quick freezer

    Ice Capacity (kg)

    1000kg in a 24hr period (vapor condenser capacity)

    Vapor Condenser Temperature (℃)

    -45℃ (option: -60℃)

    Usable Shelf Area (m2)

    100.9 m2

    Number of Shelves

    17+1, the top plate provides radiant heat only

    Shelf Dimension (mm)

    4950*(600*2)mm (thickness: 15mm) aluminum

    Shelf Spacing (mm)

    60-80mm

    Shelf Temperature (℃)

    Room temperature to 110℃(max.)

    IQF Cooling Rate (+40℃ to –25℃)

    ≤ 60 minutes

    Shelf Heating Rate (℃/min) (approx.)

    1℃/min, By electricity or steam

    Heating/cooling medium

    Silicone oil or mixing liquid

    Heating/cooling exchange

    By plate type of heat exchanger

    Number of Product Trays

    272 pieces

    Tray Dimension (mm)

    618*600mm (height: 25mm) aluminum

    Ultimate vacuum level (Pa)

    15 Pa

    Chamber vacuum rate (atm to 100 Pa)

    ≤ 25 minutes

    Refrigeration

    Brand option: Hanbell, Refcomb, Frascold, Bitzer.

    Refrigerant

    R404A/R507

    Cooling way

    By water cooling or air cooling as option

    Cooling water flow rate

    90-110t/hr,<28℃

    Vacuum system

    Standard Yihua, Yoivac, Option: Ulvac/Edwards

    Energy consumption (24hr)

    3.27kWh/kg by water cooling

    Power requirement

    170.2kw, 110-240V single, 240-480V, 3P, 50/60Hz

    Defrost way

    By water or 60°C hot water

    Control system

    PLC with HMI

    Installation area (m2)

    200 m2

    Chamber – over all dimension

    10800*2560*3200mm (L*W*H), SUS304

    Weight (kg)

    18000kg

    Contact Us

    Plot No. 3, Door No. 1/150, Kamakshi Nagar, Mugalivakkam, Chennai, Tamil Nadu, 600125, India
    Phone :+918068091910